The LOG114 is specifically designed for measuring low-level and wide dynamic range currents in communications, lasers, medical, and industrial systems. The device computes the logarithm or log-ratio of an input current or voltage relative to a reference current or voltage (logarithmic transimpedance amplifier).
High precision is ensured over a wide dynamic range of input signals on either bipolar (±5V) or single (+5V) supply. Special temperature drift compensation circuitry is included on-chip. In log-ratio applications, the signal current may be from a high impedance source such as a photodiode or resistor in series with a low impedance voltage source. The reference current is provided by a resistor in series with a precision internal voltage reference, photo diode, or active current source.
The output signal at VLOGOUT has a scale factor of 0.375V out per decade of input current, which limits the output so that it fits within a 5V or 10V range. The output can be scaled and offset with one of the available additional amplifiers, so it matches a wide variety of ADC input ranges. Stable dc performance allows accurate measurement of low-level signals over a wide temperature range. The LOG114 is specified over a -5°C to +75°C temperature range and can operate from -40°C to +85°C.
| Scale factor (V/decade) | 0.375 |
| Input current range (min) (nA) | 0.1 |
| Input current range (max) (mA) | 10 |
| Offset voltage (input amplifiers) (max) (mV) | 4 |
| Vs (±) (min) (V) | 4.8 |
| Vs (±) (max) (V) | 11 |
| Iq (max) (mA) | 15 |
| Dynamic range (typ) (dB) | 160 |
| Reference type | Internal |
| Auxiliary op amps | 2 |
| Full-scale output voltage (min) (±V) | -4.4 |
| Full-scale output voltage (max) (±V) | 4.4 |
| Conformity error (initial 5 decades) (max) (%) | 0.2 |
| Conformity error (initial 5 decades) (typ. over temp) (%/°C) | 0.1 |
| Operating temperature range (°C) | 0 to 70 |
| Specified voltage (±V) | 5 |
| Rating | Catalog |
| VQFN (RGV) | 16 | 16 mm² 4 x 4 |